Design of Steel Structure Lifting Lugs

Load Calculation - Plate Thickness - Verification Workflow

A lifting lug is small, but it is the make-or-break point of a lift - one missed check can leave a thousand-ton member hanging by a thread. This article walks through the complete closed loop of lifting lug design: calculation, plate selection, verification and re-check.

01 Lifting Lug Calculation

The calculation of a lifting lug for a steel structure is carried out by checking the lug plate, the connecting weld and the lug section for tension, shear and stability. As a critical step in any lifting operation, it must be based on GB 50017 (Standard for Design of Steel Structures) and other current applicable codes. The specific steps and verification methods are set out below.

1.1 Load and Force Calculation

Before calculating, determine the forces acting on the lug from the member weight, the sling angle and the safety factor. The three expressions below give the vertical load, the horizontal load and the total load along the sling direction.

F_N = K × F_k

where K is the lifting safety factor or dynamic load factor, normally taken as 1.35 to 1.65 (or 1.3 to 1.5), and F_k is the lifting weight carried by a single lug.

F_V = F_N × tan α

where α is the angle between the sling and the vertical.

F = F_N / cos α

where F is the total load acting along the sling.

1.2 Lifting Lug Plate Calculation

(1) Constructional Requirements and Equivalent Thickness

If a reinforcing pad is used, first calculate the equivalent thickness of the lug plate and verify that the hole edge distance b and the lug hole edge distance a satisfy the minimum constructional requirements.

t = S + S1 × (D1 - D) / a

where S is the lug plate thickness, S1 the reinforcing pad thickness, D1 the pad hole diameter, D the lifting hole diameter, and a the distance from the hole edge to the plate edge.

(2) Tensile Strength at the Net Hole Section

σ = F / (2 · t · b1) ≤ f

Check the most unfavourable section (section M or at the lifting hole) for tension; b1 is the net section width and f is the design tensile strength of the material.

(3) Tensile (Splitting) Strength of the Lug End Section

σ = F / [ 2t (a - 2D/3) ] ≤ f

Verify whether splitting failure occurs at the end of the lifting lug.

(4) Shear Strength of the Lug Plate

τ = F / (2 · t · Z) ≤ f_v

Z is the width of the shear section at the lug end and f_v is the design shear strength.

1.3 Weld Connection Calculation

The weld connecting the lug to the parent material or the backing plate (a fillet weld or a full-penetration groove butt weld) must be checked for strength. The two expressions below cover tension/compression and combined stress in fillet welds respectively.

(1) Tension / Compression Check

σ = N / (l_w · t) ≤ f_t^w / f_c^w

N is the axial force, l_w the effective weld length, t the thickness of the connected part, and f_t^w and f_c^w the design tensile and compressive strengths of the weld.

(2) Combined Stress in Fillet Welds

√{ [ (σ_N + σ_M) / β_f ]^2 + τ_V^2 } ≤ f_f^w

σ_N, σ_M and τ_V are the stresses due to axial force, bending moment and shear force respectively; β_f is the strength increase factor for front fillet welds and f_f^w is the design strength of the fillet weld. If the check fails, increase the leg size or the weld length and re-check.

02 Lifting Lug Plate Dimensions

Lifting lug dimensions (plate thickness, spacing and layout) are not fixed values; they must be selected and verified against the lifting weight, the member type and the wire rope angle. The plate thickness table and layout requirements are given below.

2.1 Lug Plate Thickness (by Member and Load)

Lug Plate Thickness Applicable Scope
16 mm Steel columns under 9 t
20 mm Steel columns of 9 t to 15 t, or steel beams under 6 t
30 mm Heavier members such as truss girders
Connection Plate Normally 16 mm steel plate

2.2 Structural and Layout Requirements

■ Lug spacing: unless there are special circumstances, the design is normally less than 6 m.

■ Wire rope length: in turnover schemes generally not less than 6 m (8 m is typical).

■ Wire rope angle: during lifting, the angle to the horizontal must exceed 60°.

■ Installation angle: install the lug inclined along the same axis as the wire rope wherever possible, to eliminate shear and bending stresses; vertical installation requires additional checks.

2.3 Material Requirements

Lifting lugs and connection plates are normally made from Q345, Q345B or AH36 (shipbuilding plate) steel of equivalent grade.

Never use Q235 or Grade A steel plate. The material grade is directly related to lifting safety, so verify it carefully during selection and re-check.

03 Calculation Workflow and Precautions

3.1 Calculation Workflow

01 Determine the member weight, the number of lifting points, the load carried by a single lug, and the angle α between the sling and the vertical.

02 Calculate the vertical load F_N, the horizontal load F_V and the total load F along the sling using the safety factor.

03 Preliminarily select the lug plate thickness and geometry, then check tensile strength at the net hole section, end splitting and shear strength.

04 Check the combined stress in the weld connecting the lug to the member.

05 If any check fails, increase the plate thickness, adjust the geometry or strengthen the weld, then re-check until all requirements are met.

3.2 Precautions

■ All calculations must be based on current codes and use design values, with a properly justified safety factor.

■ Machining, welding and installation quality of lifting lugs directly affect lifting safety; quality inspection shall be carried out to the design requirements.

■ Before lifting, visually inspect every lug and confirm it is free of cracks, deformation and other defects before use.

Safety Lands Only When the Loop Is Closed

Only when the loop of calculation - selection - verification - re-check is closed does safety truly land on every weld.